Which low-slope system suits the building

The membrane is chosen for the building, the equipment on it and how it drains. Get those three right and the brand argument mostly disappears.

Your answers

Water still standing more than about two days after rain counts as ponding.

This works out an answer as you change the controls, which needs JavaScript. Without it, the reference section below covers the same ground, and we are happy to talk it through.

The five systems, plainly

SystemWhere it belongsWhat to know
TPOLarge simple planes, warehouse and retailHeat-welded seams, reflective surface. The volume choice, and a good one when the building suits it.
PVCRestaurants, labs, anywhere with grease or chemical exhaustChemically resistant and heat-welded. The right answer where TPO and EPDM would be degraded.
EPDMSimple rectangles with few penetrationsMature, economical, easy to repair. Attention goes to seams and terminations.
Modified bitumenRoofs with heavy foot traffic and lots of detailTakes traffic well and patches easily in place, which matters on an occupied building.
Standing seam metalVisible rooflines, long horizons, few penetrationsOutlives membranes by a wide margin on the right building; wrong on a roof crowded with equipment.

Four of the five join their sheets differently, and the drawing below cuts through each lap so the distinction the ranking turns on is visible.

Flat roof seams by system Sections through four commercial membrane seams: heat-welded TPO and PVC laps, an EPDM lap joined with primer and seam tape, and staggered modified bitumen plies with a bitumen bead at the lap. Most flat-roof leaks start at seams. How a seam is madedecides how it ages. TPOHeat-welded. The two sheetsfuse into one piece.PVCHeat-welded like TPO, and holdsup to grease and chemicals. Theusual pick under restaurant exhaust.EPDMRubber sheets joined with primerand seam tape. Aging seams arethe first thing to check.Modified bitumenLayered plies bonded with a torchor adhesive. Laps are staggeredso no seam lines up.Where the sheets are joined. Sections exaggerated for clarity. C1Flat roof seams by systemIllustrative, not to scale Open full size

Ponding is a drainage defect, not a membrane choice. If water stands on the roof, the membrane over it has to tolerate that, but the thing to fix is the drainage.

Specification starts with somebody on the roof, not with a form.